Perlick Wine & Beverage Fridges Error Codes

13 error codes extracted from Perlick wine & beverage fridges service manuals. Each code includes its meaning and a summary fix step.

Error Codes13 codes

UIX

Display Communication Fault

Reset power to unit, either using rocker switch or breaker. If fault continues: Call Service: +1 844-411-8050

MEM

MC Memory Fault

Call Service: +1 844-411-8050

TCX

Extra High Condenser Temperature

Call Service: +1 844-411-8050

TEX

Evaporator temperature exceeds safe operation zone

Call Service: +1 844-411-8050

TEY

Extra Low Evaporator Temperature

Run a manual defrost for unit. If the alarm repeats within a week: Call Service: +1 844-411-8050

DO2

Door Opening Long Period

Close the door and activate a defrost cycle.

P1F

Zone 1 Probe Fault

Acknowledge code. If the alarm repeats within a week: Call Service: +1 844-411-8050

P2F

Zone 2 Probe Fault

Acknowledge code. If the alarm repeats within a week: Call Service: +1 844-411-8050

PEF

Evaporator Probe Fault

Acknowledge code. If the alarm repeats within a week: Call Service: +1 844-411-8050

TCL

Low Condenser Temperature

Verify ambient temperature was above set point of the unit, if below set point see winterizing unit instructions.

PWR

Power Outage

Verify that all temperature sensitive product did not spoil during power loss.

PCF

Condenser Temperature Fault

Acknowledge code. If the alarm repeats within a week: Call Service: +1 844-411-8050

PHF

Humidity Sensor Fault

Acknowledge code. If the alarm repeats within a week: Call Service: +1 844-411-8050

All Wine & Beverage Fridges Error CodesAll Perlick Products

Need model-specific Perlick error codes?

Access per-model error codes, part numbers, and detailed fix steps via the Covala API.